BBel's profile - overview
Registered User | |
---|---|
real name | Bert Belmans |
member since | 2015-06-22 04:16:16 -0500 |
last seen | 2019-06-24 05:26:29 -0500 |
website | www.vub.ac.be/ARCH/ae-lab/home |
location |
Brussels,
Belgium
![]() |
todays unused votes | 30 |
votes | 424 0 |
Ir. arch.Bert Belmans is a PhD researcher at the Department of Architectural Engineering of the Vrije Universiteit Brussel (VUB). He obtained the degree of “Master of Sciences in Architectural Engineering” at the VUB in 2011. The following two years he worked as an apprentice in an architectural office. He started his PhD research under the supervision of prof. dr. ir. arch. Filip Descamps in January 2014. His research focuses on the development of an optimized, context-based, control system for an adaptive hybrid ventilation system.
13 Questions
367
views
1
answer
6
votes
2016-02-05 16:44:57 -0500 aaron

Visualisation of airflow network calculation convergence in E+?
640
views
1
answer
5
votes
2015-07-16 09:38:29 -0500 Neal Kruis

Why doesn't the EnergyPlus Environment:Site Wind Speed correspond to the wind speed in the epw weather file if the boundary conditions are the same?
292
views
no
answers
4
votes
2017-05-08 15:11:42 -0500 BBel

Update: How to model a heatexchanger inside an airflownetwork?
458
views
1
answer
3
votes
2016-03-23 16:41:08 -0500 BBel

Is it possible to model an airloop with zones in series instead of in parallel in E+ - Revised
439
views
2
answers
3
votes
2019-01-30 02:22:00 -0500 BBel

Modelling vents in Energyplus Airflow network
283
views
2
answers
2
votes
2017-06-05 06:28:23 -0500 BBel

Scheduled fan flow rate in multizone model
6
views
no
answers
2
votes
2017-05-04 04:28:32 -0500 BBel

What is the link between AFN Linkage Mass Flow Rate [kg/s] and System Node Mass Flow Rates? [closed]
274
views
1
answer
2
votes
2017-09-11 03:09:34 -0500 Chandan Sharma

Zone Contaminant Source or Sink CO2 Gain seems to be wrong
224
views
2
answers
2
votes
2016-06-13 05:38:48 -0500 Chandan Sharma

Can ems lookup schedule values before or after the current timestep?
8 Answers
33 Tags
- energyplus ×48
- airflow-network ×29
- openstudio ×9
- ems ×7
- multi-zone ×7
- air-loop ×7
- residential ×5
- hvac-loop ×5
- convergence ×4
- flow-rate ×3
- fan ×3
- schedule ×3
- hvac-control ×3
- idf-file ×3
- debugging ×2
- co2 ×2
- shading ×2
- linux ×2
- error ×2
- exhaust-fan ×2
- source-code ×2
- weather-file ×2
- infiltration ×1
- slab ×1
- ventilation ×1
11 Badges
Teacher
×1
Supporter
×1
Student
×1
Scholar
×1
Organizer
×1
Enthusiast
×1
Editor
×1
Critic
×1
Commentator
×1
Civic Duty
×1