After a little more investigation, I found that the bug occurs when the following two conditions are met:
ZoneHVAC:TerminalUnit:VariableRefrigerantFlow
in the AirLoop andZoneHVAC:TerminalUnit:VariableRefrigerantFlow
in some zones are connected to the sameAirConditioner:VariableRefrigerantFlow
- There is another
AirLoopHVAC
which does not haveZoneHVAC:TerminalUnit:VariableRefrigerantFlow
.
I have narrowed down the cause of the bug to some extent, which is OK for me for now.